ASTM E 162: surface flammability of materials using a radiant heat energy source
Standard name --ASTME162/ASTM E 162
ASTM E 162: Standard test method for surface flammability of materials using a radiant heat energy source.
Test Method --ASTME162/ASTM E 162
According to ASTM E 162 standard using a radiant heat source for surface flammability test, radiant heat panels is 12 * 18 feet, radiant heat source placed on the front panel samples, Samples close to the ignition source. Board index calculated radiation: Is, the sample flame spread factor Fs, the heat change factor Q, as follows
Is=Fs*Q 及Q = CT/ß
Fs=1+1/t3+1/(t6-t3)+1/(t9-t6) +1/(t12-t9) +1/(t15-12)
This test method is applied to NFPA130 fire performance testing part.
Test data requirements: Is ≤ 25 or Is ≤ 35
ASTM E162/NFPA130 other standard
ASTM E162: standard test method for surface flammability of materials
ASTM E662: smoke density test
ASTM E648: Standard Test Method for Critical Radiant Flux of Floor-Covering Systems Using a Radiant Heat Energy Source
BSS7239: Test method for toxic gas generation by materials on combustion