首页    EU Standard    EN45545-2 Cable testing-EN 45545-2 R15/R16

EN45545-2 Cable testing-EN 45545-2 R15/R16

1. Standard name—Cable testing for EN45545-2 / EN 45545-2:2013+A1:2015

EN 45545-2 Railway applications-Fire protection on railway vehicles Part 2: Requirements for fire behaviour of materials and components.

 

EN 45545-2 according to the product end-use, divided into R1-R26, R15-Interior cable, R16-Exterior cable.

 

As the cable flame spread and burning rate of destruction of the length of the combustion smoke density (light penetration) and the burning of hazardous toxic gas escape on the staff of life play a very important influence. In general, testing cables through these areas to assess.

 

2. Test Standard and item—Cable testing for EN45545-2 / EN 45545-2:2013+A1:2015

Type

Product

Test Item

Test Standard

EN45545-2 R15 &

EN45545-2 R16

wires or cables

Vertical flame propagation for single wire or cable

EN 60332-1-2

Vertical flame spread of bunched wires or cables

EN 50266-2-4 or

EN 50305 9.1.1 or

EN 50305 9.1.2

Smoke density test

EN 61034-2

Toxicity test

EN 50305

 

3. Cable testing standard for N45545-2 / EN 45545-2:2013+A1:2015

BS EN 50266-2-4: Common test methods for cables under fire conditions - Test for vertical flame spread of vertically-mounted bunched wires or cables - Procedures - Category C (cable diameter ≥12mm)

 

BS EN 50266-2-5: Common test methods for cables under fire conditions - Test for vertical flame spread of vertically-mounted bunched wires or cables - Procedures - Category D (cable diameter 12mm)

 

EN 50306 Section 9.1.1: Railway applications-Railway rolling stock cables having special fire performance-thin wall (6mmcable diameter12mm)

 

EN 50306 Section 9.1.2: Railway applications-Railway rolling stock cables having special fire performance-thin wall (cable diameter≤6mm)

 

DIN EN 60332-1-2: DIN EN 60332-1-2: Tests on electric and optical fibre cables under fire conditions—Part 1-2: Test for vertical flame propagation for a single insulated wire or cable—Procedure for 1 KW pre-mixed flame and is for general use

 

EN 61034-2: smoke density

EN 50268-2: smoke density

NF X 70-100 600 CIT cable: toxicity testing

 

EN45545 

EN45545-Fire protection of railway vehicles

EN45545-1 Part1:Gerneral

EN45545-2 Part2:Requirements for fire behaviour of materials and components

EN45545-3 Part3:Fire resistance  requirement for  fire barriers and partitions

EN45545-5 Part5:Fire safety requirements for electrical equipment including that of trolley buses, track guided and magnetic levitation vehicles

EN45545-6 Part 6:Fire control and management system

EN45545-7 Part7:Fire safety requirements for flammable liquid and flammable gas installations

 