EN ISO 9239-1:2010 floor-covering Reaction to fire tests
1. EN ISO 9239-1:2010—Standard
ISO EN 9239-1: Reaction to fire tests-Horizontal surface spread of flame on floor-covering systems-Part 1: Flame spread using a radiant heat ignition source.
The method standard is similar with GB/T 11785:2005, EN ISO 9239-1:2010 revised EN ISO 9239-1: 2002 floor-covering Reaction to fire tests
2. EN ISO 9239-1:2010 test method
This standard specifies the performance assessment of the ground material combustion method. The method is burning in the test box, with a small flame ignited horizontally and exposed to 30 ° tilt in the heat radiation plate surface material, to assess their ability to fire spread. This method is suitable for a variety of ground materials (including substrate) of the combustion performance.
Based on the thermal radiation curve, the observed flame propagation distance converted KW/ Sample did not ignite or flame spread not more than 110mm, it's critical heat flux ≥ 11 KW/m2, sample flame spread distance of more than 910mm, it's critical heat flux ≤ 1.1 KW/m2.m2, calculating the critical heat radiation, accurate to 0.2 KW/m2.
3. EN ISO 9239-1:2010 Classification
Floor coverings flame rating SF1-SF3 (SF1, SF2, SF3), according to DIN 4102-14 or DIN EN ISO 9239-1
DIN 4102-14 can also be used to test the smoke optical density
|
Classification |
SF1 |
SF2 |
SF3 |
|
CHF |
≥2.5KW/m2 |
≥2.5KW/m2 |
≥4.5KW/m2 |
|
Smoke |
No requirement |
≤2500(%*min) |
≤750(%*min) |
4. Application ISO EN 9239-1Fire testing materials
Flooring, floor coating materials
Rubber flooring, PVC flooring
Plastic flooring, plastic flooring
Carpet
Aluminum honeycomb panel
Other ground cover material