首页    German Standard    DIN EN 50305 Se9.1.2 vertical flame spread of bunched cables

DIN EN 50305 Se9.1.2 vertical flame spread of bunched cables

DIN EN 50305 Se9.1.2 vertical flame spread of bunched cables

DIN5510-2 Table 6(Requirements on electric cables and wires), test category D for diameters≤6mm. According to DIN EN 50305 section9.1.2 standard to DIN5510-2 cable bundle testing.


DIN EN 50305 Se9.1.2/DIN5510-2 vertical flame spread of bunched cables--Standard

DIN EN 50305 section 9.1.2: wire and cable bundles of multiple vertical flame (cable diameter≤6mm) the need for this test cables and wires (not including cable), combustion test cable length does not exceed the maximum damage 1.5m.

DIN 5510-2:2009-05: preventive fire protect in railway vehicle parts 2: Fire behaviour and fireside effects of material and parts-Classification, requirements and test methods.


DIN EN 50305 Se9.1.2/DIN5510-2 vertical flame spread of bunched cables—test method

DIN EN 50305 Se9.1.2 according to the destruction after burning to assess. DIN EN DIN EN 50305 Se9.1.2 is used for DIN 5510-2 standards. DIN5510-2 Standard requirement: destruction≤1.5m.


DIN EN 50305 Se9.1.2/DIN5510-2—Other standard:

EN 50266-1 common test methods for cables under fire conditions—Test for vertical flame spread of vertically-mounted bunched wired or cables-Part 1: apparatus. 

DIN EN 50266-2-4: wire and cable bundles of multiple vertical flame (cable diameter ≥ 12mm), the need for this test cables and wires (not including cable), burning the maximum damage after the test cable length of less than 2.5 m. 

DIN EN 50305 section 9.1.1: wire and cable bundles of multiple vertical flame (6mm <cable diameter <12mm) the need for this test cables and wires (not including cable), combustion test cable length does not exceed the maximum damage 2.5m. 

DIN EN 50305 section 9.1.2: wire and cable bundles of multiple vertical flame (diameter ≤ 6mm cable required for this test cables and wires (not including cable), burning the maximum damage after the test cable length of no more than 2.5m. 

DIN EN 60332-1-2: a single vertical wire and cable flame, the need for this test cables and wires, including the data line (fiber optic cables, data bus wire, coaxial cable), combustion tests, the cable length of the top damage not more than 50mm, the bottom does not exceed 540mm.

DIN EN 61034-2: Measurement of smoke density of cables burning under defined conditions---Part 2: Test procedure and requirement. 