NFX70-100/NF X 70-100: Toxicity Testing
1. Standard-- NFX70-100/NF X 70-100
NF X 70-100: Fire behaviour tests –Analysis of pyrolysis and combustion gases-Pipe still method.
The test is conducted within a tube furnace where the temperature is set at either 400°C, 600°C or 800°C (commonly600°C is used for most materials or 800°C in the case of some electrical products). 40 minutes throughout the test. By (CO, CO2, HCI, HBr, HCN, HF, SO2) analysis of these gases toxicity index.
2. NFX70-100/NF X 70-100 for assessing F classification (smoke density and toxicity)
NF X 10-702 for assessing F classification (smoke density and toxicity)
NF F 16-101:1988 referenced in this standard (NF X 70-100) and the NF X 10-702 for the F-level smoke toxicity testing
According to NF X 70-100 and NF X 10-702 results of two tests to assess the toxicity of F-class level of F0-F5 smoke six levels (F0, F1, F2, F3, F4, F5)
F0 Class, Value of S.I.≤5; F1 Class, Value of S.I.≤20; F2 Class, Value of S.I.≤40; F3 Class, Value of S.I.≤80; F4 Class, Value of S.I.≤120; F5 Class, Value of S.I.>120.
3. NFX70-100/NF X 70-100 test methods
NF X 10-702: Fire test methods-Smoke emission-Test of measurement of specific optical density of smoke by the combustion or the pyrolysis of solid materials.
NF X 70-100: Fire behaviour tests –Analysis of pyrolysis and combustion gases-Pipe still method.
NF F 16-101: Railway rolling stock fire behaviour choice of materials
NF F 16-102: Railway rolling stock fire behaviour choice of materials-Electrical Equipment
Tel: (+86) 25 86583475 (+86) 400 6036575
Web: www.fire-test.com www.fire-test.cn
Email: info@fire-test.com
WeChat Official-"firetest" or "睿督防火测试"
...