专业提供英国阻燃测试、法国阻燃测试、德国阻燃测试、欧盟阻燃测试、美国阻燃测试、意大利阻燃测试、船舶阻燃测试、国标阻燃测试、飞机阻燃测试

联系我们

电话:400-603-6575
          025-86583475
邮箱:info@fire-test.com

地址:江苏省南京市建邺区江东中路              118号德盈大厦16F

相关测试

测试标准

首页    Regulations    BS476-6/BS 476-6:1989+A1:2009 fire propagation

BS476-6/BS 476-6:1989+A1:2009 fire propagation

BS 476-6: Fire tests on building materials and structures- Part 6: Method of test for fire propagation for products.

 

BS476-6/BS 476-6:1989+A1:2009 test method

 

This method of test, the result being expressed as a fire propagation index, provides a comparative measure of the contribution to the growth of fire made by an essentially flat material, composite or assembly. It is used primarily for the assessment of the performance of wall and ceiling linings. Fire propagation is determined by exposing the specimen to the fourteen jets of a gas pipe burner at a distance of 3mm.The heat evolved is 530J/s. The two electric elements with a total output of 1800W are switched on after two minutes forty-five seconds test duration. Their output is reduced to 1500Wat five minutes test duration and then maintained constant until the end of the test (twenty minutes).

 

The two curves are evaluated by establishing the temperatures from the calibration curve and test curve at:

       Thirty second intervals from the start of the test to three minutes test duration

       One minute intervals from four minutes to ten minutes test duration

       Two minute intervals from twelve minutes to twenty minutes test duration

The total index I = i1 + i2 + i3

 

Some high construction, I index no more than 20 or materials of class 0

Materials of Class o, i6I12

 

BS 6853/BS 476-6:1989+A1:2009 Classification requirement

BS 6853:1999 requirement:

I12, i6

 

BS476-6/BS 476-6:1989+A1:2009 reference standard

BS 476: Fire tests on building materials and structures.

BS 476-3:2004 external fire exposure roof test

BS 476-4:1970 Non-combustibility test for materials

BS 476-5:1979 Method of test of ignitability

BS476-6:1989+A1:2009 Method of test for propagation for materials

BS 476-7:1997 Surface spread of flame test for material

 

BS 476-11:1982 Method for assessing the heat emission from building materials

BS 476-12:1991 Ignitability of products by direct flame impingement

BS 476-15:1992 Method for measuring heat release of products-cone calorimeter

BS 476-20:1987 Method for determination of the fire resistance of elements of construction (general principles)

BS 476-21:1987 Methods for determination of the fire resistance of loadbearing elements of construction

BS 476-22:1987 Methods for determination of the fire resistance of non-loadbearing elements of construction

 

Tel: (+86) 25 86583475     (+86) 400 6036575