Railway rolling stock for DIN5510-2 test, test item and test standard?
DIN 5510-2:2009-05 Preventive fire protect in railway vehicle, part 2: Classification, requirement and test method.
Railway rolling stock for DIN5510-2 test contain four tests: flammability test、smoke development test、droplet test、Toxicity test。
flammability test、smoke development test and droplet test according to DIN 54837:2007 standard, test method: DIN E 54837, Sample: 500mm*190mm.
flammability test: S2-S5(S2、S3、S4、S5); Smoke development classification: not meet the SR1,SR1-SR2; Droplet testing: ST1-ST2.
DIN 5510-2 Toxicity test : FED (tzul)≤1,Test method: DIN EN ISO 5659-2, Sample: 75mm*75mm
Detail information, please contact to Nanjing Smart Technology Co., ltd
Tel: (+86) 25 86583475 (+86) 400 6036575
Web: www.fire-test.com www.fire-test.cn
Email: info@fire-test.com